100 mm Z-Stage: Installation and Calibration Guide

100 mm Z-Stage: Installation and Calibration Guide

Learn how to install and calibrate the 100 mm Z-Stage for ZeGage systems. This guide covers setup basics, compatibility, and what to check before use.

What the 100 mm Z-Stage Is For

The 100 mm Z-Stage is a spare part designed for ZeGage systems. It provides vertical positioning with a 100 mm range and includes a brake to hold position when not actively moving. This guide covers what you need to know about installing and calibrating this stage, based on the available product information.

Product Facts

  • 100 mm Z-Stage: The 100 mm Z-Stage is a spare part designed for use with ZeGage systems. Confirms the stage is intended only for ZeGage systems; not a universal part.
    100 mm Z-Stage
    100 mm Z-Stage
  • 100 mm Z-Stage: Configuration: with brake The brake holds vertical position when power is off or motion stops, which is important for calibration stability.
  • 100 mm Z-Stage: SKU: 1520-500-181 Use this SKU to order the correct standard configuration for your ZeGage system.

Installation Basics

The following steps are based on general practice for replacing a Z-stage on a ZeGage system. Always refer to your system's service manual for exact procedures.

  1. Verify compatibility: Ensure your system is a ZeGage model. The 100 mm Z-Stage is designed specifically for ZeGage systems; it is not confirmed to work with other platforms.
  2. Power down and disconnect: Turn off the system and disconnect power before accessing the stage area. Allow any residual charge to dissipate.
  3. Remove the existing stage (if replacing): If replacing an existing Z-stage, carefully disconnect any cables and remove mounting screws. Note the orientation of the original stage.
  4. Mount the new stage: Position the 100 mm Z-Stage in the same orientation as the original. Secure with mounting screws, but do not fully tighten until alignment is checked.
  5. Connect cables: Attach any power and signal cables according to your system's documentation. The stage's brake function may require a dedicated connection.

Calibration Considerations

Calibration of the 100 mm Z-Stage involves setting the vertical reference position and verifying travel. The supplied product information does not include specific calibration steps or required values (such as encoder counts or home position offsets). For accurate calibration, consult your ZeGage system's service documentation or contact Zygo support. The brake should be engaged during calibration to prevent unintended movement.

What the Catalog Does Not Cover

The available product information does not include detailed installation instructions, torque specifications, electrical pinouts, or calibration procedures. This guide provides general setup advice based on typical practice. For exact steps, always use the service manual for your specific ZeGage model. If you are unsure about any step, stop and seek guidance from a qualified technician.